Selamat Datang di Indotrade.id
Masuk | Daftar
Anggota Prioritas Prioritas IndotradeTahun ke-16
PT. ALATLAB GLOBALINDO
http://indotrade.id/alatlab/
Informasi Kontak
Nama:

Tn. Zaenal Abidin [Penjualan]

E-mail:
Situs Web:

Pesan Instan:

Nomor Telpon:

Nomor telpon Tn. Zaenal Abidin di Jakarta

Nomor Ponsel:

Nomor ponsel Tn. Zaenal Abidin di Jakarta

Nomor Faks:

Nomor faks Tn. Zaenal Abidin di Jakarta

Alamat:

Head Office : 7th Floor Suite 0707A Patria Park, Cawang, Jakarta Timur. Marketing Office : Jl. Raya Pondok Gede no. 17B Kramat Jati, Jakarta Timur
Jakarta, Jakarta
Indonesia

Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Bahasa :

Katalog Produk

Biological Safety Cabinet Class II B2 NUAIRE, Labgard 430, USA[14 May. 2010, 7:48:51]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalAmerika Serikat

Keterangan

Labgard 430/ 435 Class II, Type B2 Biological Safety Cabinet

The Labgard 430 / 435 Combines the Ventilation of a Fume Hood with the Personnel and Product Protection of a Biological Safety Cabinet.

Features :
- 100% Stainless Steel Construction
The Labgard 430 / 435 features, all stainless steel exterior and interior construction, flow through, 100% exhaust with no internal recirculation, internal microprocessor controlled Air Flow that controls and displays cabinet Air Flows, HEPEX supply air providing a " Zero-Leak" bio-clean environment, and easily configured with the options that you require.
- Evaluated for use with Flammable liquids
The Labgard 435 Biological Safety Fume Hood, is the ONLY UL/ UL-C Classified Biological Safety Cabinet that has been evaluated for use with flammable liquids and can be safely used with any chemicals that one would normally reserve for a standard fume hood, including radio active isotopes and radionuclides
- Interlocked Blower
The Labgard 430 / 435 provides premium safety. Since the cabinet depends on a remote or plant air exhaust system for proper operation, the cabinet is internally interlocked so the internal blower will not start unless the exhaust flow is within 10% of the required Air Flow. Should the Air Flow fall below the lower 10% limit, the cabinet initiates an audible alarm and visual error messages, de-energizing the internal blower, preserving the best possible personnel protection.
- Ergonomic Comfort
Ergonomic Advancements in Biological Safety Cabinet Design. From including an integral airfoil/ armrest that provides comfort and support while manipulating items in the work zone; to optional elbow supports and lazy susans that extend the work zone beyond virtually previously unused corners of the cabinets interior, means you work smarter, with less strain and more efficiently. These are just two of dozens of ergonomic features.

Specification :
Width ( W) 77 5/ 8 ( 1972)
Depth ( D) ( Incl. Control Center) 32 7/ 8 ( 835)
Height ( H) ( Incl. Exh Filter Fastener) 61 ( 1549)
Basestand, 30" W.S. 89 1/ 2 ( 2273)
Basestand, 36" W.S. 95 1/ 2 ( 2426)
Labgard 430 Interior BSC Dimensions NU-430-600( E) ( G)
Width ( W) 70 3/ 8 ( 1788)
Depth ( D) 23 1/ 2 ( 597)
Height ( H) 25 1/ 2 ( 648)

Anda mendapat [3] permintaan baru. Ke Menu Anggota
Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.id. Hak Cipta Dilindungi Undang-undang.